Improving the Treated Water for Water Quality and Good Tastes from Traditional and Advanced Water Treatment Plants

by HAn, Chia-Yun

Abstract (Summary)
The purpose of this research is to compare the performance for the water quality of two traditional water treatment plants (WTP) and three advanced water treatment plants (AWTP), and to investigate the treated drinking water in distribution systems in Kaohsiung area for promoting the consumers¡¦ self-confidence. Samples of the treated water from five major water supplies¡¦ WTP(noted numbers: WF1, WF2, WF3, WF4 and WF5) and the tap water at user¡¦s end were selected in planning of this work. It was the traditional WTP stage with treated drinking water and distribution systems in Kaohsiung area During 91 year to 92 year, so we conducted WF1 and WF2 of 8 times sampling and WF3, WF4 and WF5 for 2 times sampling at this stage. In and after 93 year, we conducted WF1, WF2, WF3, WF4 and WF5 of 8 times sampling from 93 year to 94year for the advanced WTP stage. The major tests related with the parameters of influencing operation condition included pH, odor (abbreviated as TON), total trihalomethane (abbreviated as THMs), haloacetic acids (abbreviated as HAAs), nitrogen (abbreviated as, NH3-N, hardness, total dissolved solid (abbreviated as TDS), alkalinity, total organic carbon (abbreviated as TOC), calcium ion, flavor profile analysis (abbreviated as FPA), and suspension observation in boiling with treated waters from two WTP , three AWTP and the tap water at user¡¦s end in a distribution system. It point out the better quality of treated water used the advanced water treatment plants than that of traditional water treatment plant. The items with improvement of water quality, including THMs, HAAs, hardness, TON, 2-MIB, TOC, alkinality and Ca ions concentration, is presented. Their efficiency for improvement are respectively 47%, 29%, 43%, 11%, 29%, 15%, 14% and 34%. The insignificant efficiency were concentrated at TDS, NH3-N, pH and FPA. Water quality of six items are fitted for the drinking water standard at present in Taiwan (such as: odor<3 TON; THMs<0.1 mg/L; NH3-N<0.1 mg/L; TDS< 600 mg/L; Hardness <400 mg as CaCO3/L; 6.0Bibliographical Information:

Advisor:C. M. Kao; C. B. Chen; J. C. Lou; S. J. Chen; T. S. Wu

School:National Sun Yat-Sen University

School Location:China - Taiwan

Source Type:Master's Thesis

Keywords:correlation analysis contour map advanced water treatment plants distribution system

ISBN:

Date of Publication:07/19/2007

© 2009 OpenThesis.org. All Rights Reserved.

Contact Us | About Us | Privacy Policy & Terms of Use